7. Reset Appliance
The following are two cases when you have to reset your appliance:
1. You forgot the administrator password
2. You move the appliance to a different network and you cannot access the appliance
because you did not change the appliance IP settings for the new network while you
could access the appliance in the previous network.
The RHUB appliance does three things during the reset:
1. It resets the system administrator account to the default one: "admin" as the email and
"password" as the password. If you have multiple administrators, it only resets the first
one's account.
2. It changes the IP settings to use DHCP.
3. It removes your own system home page URL so that you can easily access the appliance
by a new IP address.
The reset does not affect any other data including user profiles, meeting logs, scheduled
meetings, SSL certificate, audio integration setting, etc.
To reset the RHUB TM-200, TM-210, TM-260, TM-270, TM-510, TM-560, TS-300, or TW-100
appliances, you just push a pin into the reset button on the back and hold it for over 10 seconds
until the “Ready” light turns off. After about 60 seconds when the “Ready light turns on, you can
access the appliance.
To reset the RHUB TM-600, TM-800, TM-1000, or TS-700 appliances, you need to connect it with
your monitor, keyboard and mouse. The server runs in a Fedora Linux system. The default
operating system login name is "turbomeeting" and the password is "password". After logging in,
right click on the desktop and open a Terminal session. Type "./ResetTM", which resets the
appliance. Then open a browser and type "http://localhost" to access the TurboMeeting
administration pages. Use the system default account: "admin" as the email and "password" as
the password.
Refer to the Section 1.1 about how to access to your appliance after the reset.